Search results

2031 results

Sorted by Relevance . Sort by Date

  1. High-sensitivity troponin tests for the early rule out of NSTEMI (DG40)

    Evidence-based recommendations on high-sensitivity troponin tests for the early rule out of NSTEMI (non-ST-segment elevation myocardial infarction)

  2. Atrial fibrillation and heart valve disease: self-monitoring coagulation status using point-of-care coagulometers (the CoaguChek XS system) (DG14)

    Evidence-based recommendations on the CoaguChek XS system for self-monitoring coagulation status in adults and children. The recommendations originally included

  3. PlGF-based testing to help diagnose suspected pre-eclampsia (Triage PlGF test, Elecsys immunoassay sFlt-1/PlGF ratio, DELFIA Xpress PlGF 1-2-3 test, and BRAHMS sFlt-1 Kryptor/BRAHMS PlGF plus Kryptor PE ratio) (DG23)

    Evidence-based recommendations on PlGF-based testing to help diagnose suspected pre-eclampsia (Triage PlGF test, Elecsys immunoassay sFlt-1/PlGF ratio, DELFIA

  4. New generation cardiac CT scanners (Aquilion ONE, Brilliance iCT, Discovery CT750 HD and Somatom Definition Flash) for cardiac imaging in people with suspected or known coronary artery disease in whom imaging is difficult with earlier generation CT scanners (DG3)

    Evidence-based recommendations on new generation cardiac CT scanners (Aquilion ONE, Brilliance iCT, Discovery CT750 HD and Somatom Definition Flash) for cardiac

  5. Quantitative faecal immunochemical tests to guide referral for colorectal cancer in primary care (DG30)

    Evidence-based recommendations on faecal immunochemical tests (OC Sensor, HM-JACKarc, FOB Gold and RIDASCREEN) to guide GP referral for colorectal cancer

  6. Tests in secondary care to identify people at high risk of ovarian cancer (DG31)

    Evidence-based recommendations on tests in secondary care to identify people at high risk of ovarian cancer. The tests are the IOTA ADNEX model, Overa (MIA2G)

  7. Procalcitonin testing for diagnosing and monitoring sepsis (ADVIA Centaur BRAHMS PCT assay, BRAHMS PCT Sensitive Kryptor assay, Elecsys BRAHMS PCT assay, LIAISON BRAHMS PCT assay and VIDAS BRAHMS PCT assay) (DG18)

    NICE has assessed the procalcitonin tests (ADVIA Centaur BRAHMS PCT assay, BRAHMS PCT Sensitive Kryptor assay, Elecsys BRAHMS PCT assay, LIAISON BRAHMS PCT

  8. Integrated multiplex PCR tests for identifying gastrointestinal pathogens in people with suspected gastroenteritis (xTAG Gastrointestinal Pathogen Panel, FilmArray GI Panel and Faecal Pathogens B assay) (DG26)

    Evidence-based recommendations on integrated multiplex polymerase chain tests (xTAG Gastrointestinal Pathogen Panel, FilmArray GI Panel and Faecal Pathogens B

  9. Multiple frequency bioimpedance devices to guide fluid management in people with chronic kidney disease having dialysis (DG29)

    Evidence-based recommendations on multiple frequency bioimpedance devices to guide fluid management in people with chronic kidney disease having dialysis

  10. Point-of-care creatinine devices to assess kidney function before CT imaging with intravenous contrast (DG37)

    Evidence-based recommendations on point-of-care creatinine devices to assess kidney function before CT imaging with intravenous contrast. The tests are

  11. Implantable cardiac monitors to detect atrial fibrillation after cryptogenic stroke (DG41)

    Evidence-based recommendations on implantable cardiac monitors to detect atrial fibrillation after cryptogenic stroke

  12. Integrated sensor-augmented pump therapy systems for managing blood glucose levels in type 1 diabetes (the MiniMed Paradigm Veo system and the Vibe and G4 PLATINUM CGM system) (DG21)

    Evidence-based recommendations on the MiniMed Paradigm Veo and Vibe and G4 PLATINUM CGM sensor-augmented pump therapy systems, which combine continuous glucose

  13. SeHCAT (tauroselcholic [75 selenium] acid) for the investigation of diarrhoea due to bile acid malabsorption in people with diarrhoea-predominant irritable bowel syndrome (IBS-D) or Crohn's disease without ileal resection (DG7)

    Evidence-based recommendations on SeHCAT (tauroselcholic [75selenium] acid) for diagnosing bile acid malabsorption in people with IBS-D or Crohn’s disease

  14. Adjunctive colposcopy technologies for assessing suspected cervical abnormalities: the DYSIS colposcope with DYSISmap and the ZedScan I (DG32)

    Evidence-based recommendations on 2 adjunctive colposcopy technologies (the DYSIS colposcope with DYSISmap and the ZedScan I) for assessing suspected cervical

  15. Biomarker tests to help diagnose preterm labour in women with intact membranes (DG33)

    Evidence-based recommendations on biomarker tests to help diagnose preterm labour in women with intact membranes. The tests are Actim Partus, PartoSure and the

  16. SonoVue (sulphur hexafluoride microbubbles) – contrast agent for contrast-enhanced ultrasound imaging of the liver (DG5)

    Evidence-based recommendations on SonoVue (sulphur hexafluoride microbubbles) for contrast-enhanced ultrasound imaging of the liver

  17. Tests to help assess risk of acute kidney injury for people being considered for critical care admission (ARCHITECT and Alinity i Urine NGAL assays, BioPorto NGAL test and NephroCheck test) (DG39)

    Evidence-based recommendations on tests to help assess risk of acute kidney injury for people being considered for critical care admission. The tests are the

  18. Rapid tests for group A streptococcal infections in people with a sore throat (DG38)

    Evidence-based recommendations on rapid tests for group A streptococcal infections in people aged 5 and over with a sore throat

  19. Therapeutic monitoring of TNF-alpha inhibitors in rheumatoid arthritis (DG36)

    Evidence-based recommendations on enzyme-linked immunosorbent assay (ELISA) tests for therapeutic monitoring of tumour necrosis factor (TNF)-alpha inhibitors in

  20. Lead-I ECG devices for detecting symptomatic atrial fibrillation using single time point testing in primary care (DG35)

    Evidence-based recommendations on lead-I electrocardiogram (ECG) devices (imPulse, Kardia Mobile, MyDiagnostick and Zenicor-ECG) for detecting symptomatic

  21. Tumour profiling tests to guide adjuvant chemotherapy decisions in early breast cancer (DG34)

    Evidence-based recommendations on tumour profiling tests to guide adjuvant chemotherapy decisions for people with early breast cancer. The tests are EndoPredict

  22. Molecular testing strategies for Lynch syndrome in people with colorectal cancer (DG27)

    Evidence-based recommendations on using immunohistochemistry or microsatellite instability testing to guide further testing for Lynch syndrome in people with

  23. Faecal calprotectin diagnostic tests for inflammatory diseases of the bowel (DG11)

    Evidence-based recommendations on faecal calprotectin tests for distinguishing between inflammatory bowel diseases (such as Crohn’s disease and ulcerative

  24. Measuring fractional exhaled nitric oxide concentration in asthma: NIOX MINO, NIOX VERO and NObreath (DG12)

    Evidence-based recommendations on NIOX MINO, NIOX VERO and NObreath for measuring the amount of exhaled nitric oxide (FeNO) in the breath to help diagnose

  25. Intraoperative tests (RD‑100i OSNA system and Metasin test) for detecting sentinel lymph node metastases in breast cancer (DG8)

    Evidence-based recommendations on the RD-100i OSNA system and Metasin test for detecting sentinel lymph node metastases in people having breast cancer surgery

  26. EGFR‑TK mutation testing in adults with locally advanced or metastatic non-small-cell lung cancer (DG9)

    Evidence-based recommendations on testing for epidermal growth factor receptor tyrosine kinase (EGFR–TK) mutations in untreated, locally advanced or metastatic

  27. Detecting, managing and monitoring haemostasis: viscoelastometric point‑of‑care testing (ROTEM, TEG and Sonoclot systems) (DG13)

    NICE has assessed 3 viscoelastometric point-of-care testing devices (the ROTEM, TEG and Sonoclot systems), to help the NHS decide whether to use these products

  28. Fluorouracil chemotherapy: The My5‑FU assay for guiding dose adjustment (DG16)

    Evidence-based recommendations on the My5-FU assay for measuring levels of 5-flurouracil (5-FU) in patients having chemotherapy, to help guide changes to the

  29. Therapeutic monitoring of TNF-alpha inhibitors in Crohn's disease (LISA-TRACKER ELISA kits, IDKmonitor ELISA kits, and Promonitor ELISA kits) (DG22)

    Evidence-based recommendations on therapeutic monitoring of tumour necrosis factor (TNF)-alpha inhibitors (LISA-TRACKER, IDKmonitor and Promonitor ELISA kits)

  30. Depth of anaesthesia monitors – Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M (DG6)

    Evidence-based recommendations on 3 electroencephalography (EEG)-based depth of anaesthesia monitors for assessing a patient’s response to anaesthetic drugs